Product Details:
Payment & Shipping Terms:
|
Principle: | NF Type Eddy Current / F Magnetic Induction | Range: | 0~1250µm/0~50mil |
---|---|---|---|
Resolution: | 0.1µm/1µm | Accuracy: | ±1~3%n Or ±2.5µm |
Min.Radius Workpiece: | F Type:convex 1.5mm/concave 25mm/ NF Type:convex 3mm/concave 50mm | Battery Indicator: | Low Battery Indicator |
Highlight: | non destructive testing machine,portable surface roughness tester |
Magnetic Induction (F) and Eddy Current (N) Coating
Thickness Gauge CM-8826
Technical Data Download: iqualitrol Coating Thickness Gauge CM-8826
Brief Introduction:
The F probes measure the thickness of non-magnetic materials on magnetic materials.
The N probes measure the thickness of non-conductive coatings on non-magnetic metals.
Features:
Two measuring methods: magnetic induction (F) and eddy current (N)
Two measurement mode: Single and Continuous(Notice:Continuous mode is convenient to measure the coating thickness of curved objects and tiny objects.)
Metric/imperial system selectable.
Manual or automatic shut down.
Automatic memory of calibration value,and automatic recognize the substrate.
Operation process have buzzing reminder,while no buzzing in continuous mode.
Use USB/RS-232 data output to connect with PC.
Provide Bluetooth data output choice.
Separate Type can provide several type probe, measure can be more flexibility.
Principle:
Principles | Applications | Examples |
F Type Magnetic Induction (Iron Base) |
Measure the thickness of non-magnetic materials on magnetic materials | Galvanizing layer, lacquer layer, porcelain enamel layer, phosphide layer, copper tile, aluminium tile, some alloy tile, paper etc |
NF Type Eddy Current (Aluminium Base) |
Measure the thickness of non-conductive coatings on non-magnetic metals | Anodizing, varnish, paint, enamel, plastic coatings, powder, etc. Applied to aluminum, brass, non-magnetic stainless steel, etc |
Technical Specifications:
Principle | NF Type Eddy Current / F Magnetic Induction |
Range | 0~1250µm/0~50mil |
Resolution | 0.1µm/1µm |
Accuracy | ±1~3%n or ±2.5µm |
Min.Radius Workpiece | F Type:convex 1.5mm/concave 25mm |
NF Type:convex 3mm/concave 50mm | |
Min.Measuring Area | 6mm |
Min.Sample Thickness | 0.3mm |
Metric/Imperial | Convertible |
Battery Indicator | Low Battery Indicator |
Automatic Power Off | √ |
Operating Conditions | Temperature:0~50ºC |
Humidity:<80%RH | |
Power Supply | 4x1.5V AAA (UM-4)Battery |
Dimensions | 126x65x27mm |
Weight | 81g(Not Including Batteries) |
More Introductions of CM8826FN:
CM8826FN is a domestic coating thickness gauge with independent intellectual property right. It can quickly and accurately detect the coating thickness on metal substrate. coating thickness measuring instrument fully conforms to ISO 2178, ISO 2360, GB/t 4956, GB/t 4957, ASTM B499 and other professionals of magnetic method and Eddy current method testing principle.
Professional version Integrated dual-use coating thickness gauge has the advantages of accurate measurement, large measuring range, multi-calibration mode, multi-measurement mode, convenient positioning and powerful function, widely used in manufacturing, metal processing, chemical industry and other surface engineering testing fields, coating surface treatment industry is the basic equipment.
The Fe-based probe can detect the thickness of non-magnetic coatings on various magnetic substrates (such as steel) , such as paint, powder, porcelain, chromium, copper, zinc, etc..
NFe based probes detect the thickness of all insulating coatings, such as paint, powder, porcelain, etc. , applied to non-magnetic metal substrates such as aluminum, copper, brass, stainless steel, etc. .
Contact Person: Mr. Raymond Chung
Tel: 86-13711988687
Fax: 86-769-22784276