Product Details:
Payment & Shipping Terms:
|
Range: | 0.50mm To 508mm | Unit: | Inch Or Millimeter |
---|---|---|---|
Velocity: | 500 To 9999m/s | Display: | 2.4” Color OLED |
Memory: | Stores 100,000 Readings And 1000 Waveform | Rectify Mode: | RF+, RF-, HALF+, HALF-, FULL |
High Light: | 0.50mm Non Destructive Testing Equipment,508mm Non Destructive Testing Equipment,OLED Screen UT Thickness Tester |
OLED Screen Echo-Echo Mode Non Destructive Ultrasonic Thickness Gauge with Color Waveform
Features:
1, Color OLED 320x240 Pixels Display;
2, Live Simultaneous Color A-Scan and Thickness Display;
3, Control of Gain, Blanking, Gate, Range, Delay, RF and Rectify Modes;
4, Time-based B-Scan Display;
5, Echo-Echo Mode(Through Paint & Coatings);
6, Stores 100,000 Readings and 1000 waveform;
Technical Specifications:
Display Type | 2.4” color OLED, 320×240 pixels, contrast 10,000:1 |
Operating Principle | Pulse echo with dual element transducers |
Measuring Range | 0.50mm to 508mm(0.02” to 20.00”), depending on material, probe and surface condition |
Resolution | Selectable 0.01mm, 0.1mm(selectable 0.001”, 0.01”) |
Units | Inch or Millimeter |
Rectify Mode | RF+, RF-, HALF+, HALF-, FULL |
Display Mode | Normal, Minimum/Maximum capture, DIFF/RR%, A-Scan, B-Scan |
V-Path Correction | Automatic |
Update Rate | Selectable 4Hz, 8Hz, 16Hz |
Material Velocity Range | 500 to 9999m/s(0.0197 to 0.3939 in/microsecond) |
Languages | English, French, German, etc. |
Alarm Settings | Minimum and Maximum alarms. Range of 0.25mm to 508 mm(0.010” to 20.00”). Dynamic waveform color change on aalarm |
Power Requirements | 2 AA size batteries |
Operating Time | Approximately 40 hours |
Instrument Shut-off | Selectable ALWAYS ON or AUTO OFF after 5, 10, 20 minutes of inactivity |
Operating Temperature | -10℃ to +50℃(+10°F to +12°F ) |
Size | 153mm × 76mm × 37mm (H × W × D) |
Weight | 280g including batteries |
Live Color A-Scan
Users could directly see the color waveform of the ultrasonic sound (or A-scan) on the screen, which is quite important for the occasions that we need to check the correctness of the testing results. Many cases will cause wrong testing results or even noreadings. We could find the causes easily through the A-scan. Adjust the three parameters of GAIN, BLACKING, GATE, and then we will get the right readings.
Live Color B-Scan
UM-5 series thickness gauge has time base B-scan function. Move the probe along the workpiece surface, then the cross -sectional profile of the workpiece display, use for observe the underside contour of the workpiece.It could be automatically capture a minimum value of the B-scan image, and indicate the position of the minimum by a red triangle. You can see any point thickness value of the B-scan image by moving the pointer.
Recitification Modes
RF+, RF-, Half+, Half-, and FULL total 5 modes selective
RF+: describe the whole echo waveform
RF-: Invert display the radio frequency signal
Half+: Show the Half -Wave positive without the Half- Wave negative
Half-: Show the Half-Wave negative without the Half-Wave positive
FULL: Show both the Half-Wave Positive and upturned Half-Wave Negative
Larger and More convenient storage capacity
It can save one hundred thousand thickness values and one thousand A/B-scan waveforms,waveform and thickness values can be mixed stored in the same file.Storage capacity is 20-200 times to the similar products.
Use grid format storing files,the screen can display 15 thickness values and show its position in the grid,which is more convenient for the users to browse the stored data of the thickness.
USB 2.0 full speed connector, powerful DataView data statistics and management software.
The Difference Between UM-5 Series Technical Specifications:
Feature | UM-5 | UM-5D | UM-5DL |
Color Display | √ |
√ |
√ |
Live A-Scan | √ |
√ |
√ |
Time-based B-Scan |
√ |
√ |
√ |
Control of Gain and Gate |
√ |
√ |
√ |
Blanking |
√ |
√ |
√ |
Through-paint&coatings |
× |
√ |
√ |
Data Logger |
× |
× |
√ |
DataView Software |
× |
× |
√ |
Standard Configuration:
Name | Quantity |
Main Unit | 1 |
Probe | 1 |
Battery | 2 |
Couplant | 1 |
Carrying Case | 1 |
Operating Manual | 1 |
USB Cable | 1(Only UM-5DL) |
Software | 1(Only UM-5DL) |
Note: Without Battery and Coupant if By Air Transportation.
Contact Person: Mr. Raymond Chung
Tel: 86-13711988687
Fax: 86-769-22784276