logo
Send Message
Home News

Choosing Humidity Ranges for Test Chambers

Certification
China Dongguan Quality Control Technology Co., Ltd. certification
China Dongguan Quality Control Technology Co., Ltd. certification
Customer Reviews
The touch screen micro vickers hardness tester has been installed a few weeks ago, everything is OK. Thanks for your advice and excellent service.

—— Mr. David Chambers

Thanks for the fast delivery and our customer is very satisfied for the rockwell hardness tester, and hope more orders soon.

—— Neil Renato

After we visited the customer, they finally decided to purchase Brinell hardness tester iBrin-413Z, now we have installed the unit at customer’s site,

—— Fermin Lee

Thank you for the indenters (diamond  cone 120 degrees). We recently got it and already tested it. Indenters  are good as we expected. 

—— Dalius Skinulis

The Measurements are good for Brinell Tester HBST-3000.

—— Sun Chull Kim

Hey, the hardness tester iVick-484ST was installed last week and works well, thanks for the professional support.

—— Sabinian Smith

I am glad to inform you that the installation of the SHB-3000C Brinell hardness tester has been finished successfully. I would like to thank you!

—— Robbin

I'm Online Chat Now
Company News
Choosing Humidity Ranges for Test Chambers
Latest company news about Choosing Humidity Ranges for Test Chambers

 

Choosing Humidity Ranges for Test Chambers

 

When we choose the equipment we need, in addition to looking at the quality and functions of the product, we also need to pay attention to which one is most suitable for us.

 

We have some things to note when choosing the humidity range of the constant temperature and humidity test chamber:

 

1. Generally speaking, ordinary constant temperature and humidity test chambers below 2m can meet the requirements of area A. The dehumidification method in area A is water pan dehumidification. Some manufacturers use evaporator dehumidification, and the humidification method is hot steam humidification (water pan humidification). /boiler humidification), the humidity sensor can use the wet and dry bulb method;

 

2. For the walk-in constant temperature and humidity test chamber assembled with warehouse boards, when the dew point temperature is ≥67°C (70°C 90%R.H), the warehouse body must be fully welded, and the initial investment cost will be high, so you can choose the product without special requirements. The dew point temperature is <67°C to reduce costs. For large walk-ins where it is inconvenient to replace gauze, it is recommended to use capacitive sensors;

 

3. The dew point temperature in area B is about 0°C, and an evaporator must be used for dehumidification. The evaporator is easy to frost, so it is not recommended to stay in this area for a long time. The wet bulb sensor that meets this area must use a capacitive sensor;

 

4. The dew point temperature in area C is lower, and dry air must be used for dehumidification. The lowest dew point temperature of dry air can reach -70°C, and the wet bulb sensor must use a capacitive sensor;

 

5. Deionized water or purified water must be used for humidification;

 

6. The wet ball gauze used for the dry and wet ball sensors must be replaced regularly;

 

7. The walk-in constant temperature and humidity test chamber consumes a lot of water, so it is recommended to choose automatic water replenishment; because the three comprehensive test chambers are inconvenient to add water, it is recommended to choose automatic water replenishment;

 

Pub Time : 2024-05-16 10:34:15 >> News list