Send Message
Home News

Instructions for Using of Metallographic Microscopes

Certification
China Dongguan Quality Control Technology Co., Ltd. certification
China Dongguan Quality Control Technology Co., Ltd. certification
Customer Reviews
The touch screen micro vickers hardness tester has been installed a few weeks ago, everything is OK. Thanks for your advice and excellent service.

—— Mr. David Chambers

Thanks for the fast delivery and our customer is very satisfied for the rockwell hardness tester, and hope more orders soon.

—— Neil Renato

After we visited the customer, they finally decided to purchase Brinell hardness tester iBrin-413Z, now we have installed the unit at customer’s site,

—— Fermin Lee

Thank you for the indenters (diamond  cone 120 degrees). We recently got it and already tested it. Indenters  are good as we expected. 

—— Dalius Skinulis

The Measurements are good for Brinell Tester HBST-3000.

—— Sun Chull Kim

Hey, the hardness tester iVick-484ST was installed last week and works well, thanks for the professional support.

—— Sabinian Smith

I am glad to inform you that the installation of the SHB-3000C Brinell hardness tester has been finished successfully. I would like to thank you!

—— Robbin

I'm Online Chat Now
Company News
Instructions for Using of Metallographic Microscopes
Latest company news about Instructions for Using of Metallographic Microscopes

 

Instructions for Using of Metallographic Microscopes

 

The metallographic microscope is an indispensable equipment in metallographic analysis. IQUALITROL iMet-224DIC equips with excellent UIS optical system and the notion of modularization function design, provide excellent optical performance and the update of the system.

 

The following are seven steps for using a metallographic microscope:

 

Installation and adjustment: Make sure the microscope is installed in a dry, ventilated, dust-free, vibration-free, and corrosion-free room, and placed on a stable table or base, preferably with a shock-absorbing device.

 

Illumination method selection: According to the purpose of observation and sample characteristics, select the appropriate lighting method, such as bright field, dark field, polarized light or differential interference contrast (DIC).

 

Lens selection: Select the appropriate objective and eyepiece combination based on the required magnification.

 

Diaphragm adjustment: Use the aperture diaphragm to adjust the size of the incident beam and light intensity, and the field diaphragm to adjust the size of the observation field of view.

 

Filter application: As needed, select appropriate filters to absorb specific wavelengths of light and improve image clarity.

 

Image acquisition and annotation: When using software for image acquisition, a ruler should be added to the image to mark the sample size.

 

Image processing and analysis MetaVision Software: After collection, adjust the brightness, contrast and grayscale transformation of the image to make the image more conducive to analysis and judgment. Regularly verify the system ruler of the image analysis software to ensure accuracy.

 

The above are the basic steps for using a metallographic microscope. The specific operations may vary depending on the microscope model and software. It is recommended to refer to the microscope's user manual for more detailed operating instructions.

 