Camera: | USB 1.3Mpx Camera | Max Force: | 10Kgf |
---|---|---|---|
Load Control: | Automatic (load/dwell/unload) | Conversion: | Refer ASTM E140 Standard |
Software: | Support Vickers And Knoop Test | Report: | In Format Word, Excel |
Highlight: | Computerized Metal Hardness Testing machine,Metal Hardness Testing machine 10Kgf |
Computerized Automatic Turret Vickers Hardness Tester with
Vickers Measuring System and 1.3Mpx USB Camera
Model: HV-10Zpc
Technical Data Download: iqualitrol Auto Turret Vickers Hardness Tester HV-10Zpc
Technical Parameters:
Vickers hardness scale | HV0.3, HV0.5, HV1.0, HV3.0, HV5.0, HV10.0 |
display | 5-digit hardness value, 4-digit diagonal length (D1, D2), Hold time, number of tests, average, standard deviation, return |
Test force(Kgf) | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 |
Loading control | Automatic (load/hold/uninstall) |
Test force retention time(s) | 1~99 |
Optical channel | Dual light channels (eyepieces and CCD camera channels) |
Optical system | Objectives: 10×, 20× Eyepiece Magnification: 10× Total magnification (μm): 100×, 200× Measuring range : 800μm 400μm Resolution : 1μm 0.5μm |
Hardness measurement range | (5-3000)HV |
XY test stand (optional) | Size (mm): 100×100 Travel range (mm): 25×25 Minimum reading (mm): 0.01 |
Maximum height of specimen (mm) | 165 |
Maximum width of specimen (mm) | 130 (distance from the center line of the indenter to the wall) |
Data output | Reserve built-in mini printer interface, (RS232 serial interface) optional installation |
Executive standard | GB/T4340.2 Chinese Standard, JJG151 Inspection Rule |
Overall size (mm) | 585×200×630 |
Weight (kg) | 42 |
Brief Introduction:
iqualitrol automatic turret-type Vickers hardness tester is a high-tech product of electromechanical and electromechanical integration. The hardness tester is novel in design, has good reliability, operability, and repeatability and is an ideal product for testing Vickers hardness.
The machine uses computer software programming, optical measurement system. Through the soft key input, the measurement of Vickers and Knoop hardness can be selected, the intensity of the measuring light source can be adjusted, the time of charge can be selected, the test method and test force can be displayed on the LCD display, and the indentation pair can be measured through the panel input. The length of the corner line and the screen directly read the hardness value, making it simple to check the table. Easy to use, high measurement accuracy
This machine can be equipped with a Vickers measuring system: continuous test for continuous reading of indentations after continuous loading, and successive experiments for each loading and each reading indentation. Using a digital camera with a convenient ccd camera, video cable, or USB interface, the measurement indentation can be directly observed on the monitor, and the accuracy can be measured with the mouse. For setting test conditions, displaying results, etc. can be operated and displayed clearly and quickly.
Through the measurement software, it can be easily operated by a computer. A single point measurement can be used to randomly measure multiple points and statistical measurement data. The distance between two or more measurement points can be arbitrarily set. Permeation layer depth measurement can be measured along X or Y directions,Statistical measurement data, according to the user input automatically determine the depth of hardened layer calculations. Statistics calculations, conversion, display curves, to determine whether the qualified. Can measure the length of the part of graphics preservation and printing.
Software features:
1. Universal USB control, self-provisioned with USB camera, supports more than 90% USB camera on the market, including chat camera, no capture card, notebook can also be used to save costs (also has a capture card version, the price is not the same , faster response, more stable, more powerful);
2. Carburized layer depth analysis, detailed report;
3, 10, 20, 40, 3 kinds of magnifications can be switched freely, and can be separated without affecting each other;
4. Replace the force without recalibration;
5, 14 kinds of E140 standard scale conversion;
6, can achieve automatic measurement;
7, magnifier function, measurement easier;
8, the force value can be freely set, there is no limit of magnification, magnification software calibration, theoretically can measure all Vickers including small load;
9, exclusive features: a hardness block to complete the calibration, eliminating the high price multiplier, more convenient, easier and more accurate.
Main functions and features of the instrument:
1.The optical system designed by senior optical engineers not only has clear images, but also can be used as a simple microscope with adjustable brightness and comfortable vision.
2. Industrial display LCD large-screen display can display year, month, day, test results and data processing test methods, test force, measuring indentation length, hardness value, test force retention time, measurement times and types;
3, Cast aluminum shell molding, structural stability is not deformed, high-grade automotive paint, scratch resistance, and use for many years is still bright as new;
4. Our company has its own R&D, production and processing capabilities. Our machines provide parts replacement and maintenance upgrades for life.
5. HV-10Z model can be realized: observation - test - completed by automatic turret measurement position switch;
Main application scope:
1. Iron and steel, non-ferrous metals, metal foils, hard alloys, metal sheets, microstructures;
2. Carburizing, nitriding and decarburization layers, surface hardened layer, plating layer, coating,;
3, glass, wafers, ceramic materials, carbonization;
Standard configuration
Host computer | 1 |
weight | 3 |
Large and medium "V" test benches | 1 |
Horizontal adjustment screw | 4 |
Power cable | 1 |
10X digital microscope eyepiece | 1 |
Vickers hardness block | 2 |
Spare fuse 2A | 2 |
Product Certificate | 1 |
Instruction Manual | 1 |