Product Details:
Payment & Shipping Terms:
|
Solution Tank: | 40L | Temperature: | CASS 50℃±1℃ |
---|---|---|---|
Spray Quantum: | 1.0~2.0(ml/80cm2/h) | Material: | Polyvinyl Chloride (PVC) |
Highlight: | Durable Salt Spray Test Chamber,Salt Spray Test Chamber ASTM B117,Salt Spray Corrosion Test Chamber |
Durable Use Salt Spray Test Chamber for CASS NSS ACSS Testing
Conform ASTM B117
Brief Introduction:
Salt Spray Test Chambers offer the most realistic and dependable corrosion test, widely used to test corrosion resistance of automotive, paint, surface coating, chemical, aerospace, electronic, car industry, offshore and defense industries.
Features:
1, Chamber material is made of P.V.C Sheet, sturdily and will not be out of shape.
2, Test chamber is heated from five directions to ensure the temperature is uniformity distributed.
3, Spray nozzle is specially made, enable to spray the salt water with considerable speed, then falls on the surface of samples.
4, Hot and moist air keeps the humidity in the test chamber conforms testing request.
5, High precision P.I.D. temperature controller limits the temperature difference within the range of ±0.1℃.
Specifications:
Please note: ZK-60 and ZK-90 do not meet standard of ASTM B117.
Model | ZK-60 | ZK-90 | ZK-120 | ZK-160 | ZK-200 | ||
Interior |
W | 600 | 900 | 1200 | 1600 | 2000 | |
D | 450 | 600 | 850 | 1000 | 1200 | ||
H | 400 | 500 | 500 | 550 | 600 | ||
Exterior dimensions |
W | 1130 | 1460 | 2200 | 2600 | 3000 | |
D | 630 | 910 | 1200 | 1450 | 1650 | ||
H | 1070 | 1280 | 1450 | 1550 | 1600 | ||
Chamber Volume | 108 L | 270 L | 480 L | 800 L | 1440 L | ||
Solution Tank | 15L | 25 L | 40 L | ||||
Power Supply | AC 220V 50HZ | AC 380V 50HZ | |||||
Ambient temp. & humid. range | +5℃ ~ +35℃ / <85%RH | ||||||
Testing Temperature | NSS ACSS 35℃±1℃ / CASS 50℃±1℃ | ||||||
Air Temperature | NSS ACSS 47℃±1℃ /CASS 63℃±1℃ | ||||||
Solution Consistence | NaCl 5% | ||||||
PH Value | NASS ACSS:6.5~7.2 / CASS:3.0~3.2 | ||||||
Temperature fluctuation | ≦±0.5℃ | ||||||
Temperature uniformity | ≦2. 0℃ | ||||||
Temperature deviation | ≦±2.0℃ | ||||||
Spray quantum | 1.0~2.0(ml/80cm2/h) | ||||||
Chamber Material | polyvinyl chloride (PVC) | ||||||
Heater | Corrosion-resistant titanium tube | ||||||
Temperature sensor | Platinum Resistance (PT-100) | ||||||
Safety device | Over-temperature protection , leakage protection |
Note: 1. The above specifications are for reference only, the actual specifications for the main quotation.
2. Custom made is available according to customers’ special requirements.
Contact Person: Mr. Raymond Chung
Tel: 86-13711988687
Fax: 86-769-22784276