Product Details:
Payment & Shipping Terms:
|
Test Mode: | Vickers And Knoop | Turret: | Automatic Turret |
---|---|---|---|
Data Output: | Built-in Mini Printer And RS232 | Illumination: | Halogen Lamp |
Dwell Time: | 0-60 Seconds, Adjustable | Magnification: | 100x, 200x, 400x |
High Light: | Digital Micro Vickers Hardness Tester,Large LCD Micro Vickers Hardness Tester,Micro Durometer |
Motorized Turret Dual Indenter Large LCD Micro Vickers Material Hardness Testing Equipment / Durometer
Technical Data Download: iqualitrol Micro Vickers Hardness Tester iVick-457HK
Product Features:
iqualitrol iVick-457HK Digital Micro Vickers hardness tester is a high-tech and new product combining the optics, mechanic and electrics features, with a novel and pleasing appearance, the internal structure is mainly made by stainless steel parts, has better performance.
iVick-457HK adopts a new type of automatic turret mechanism, equipped with both Micro Vickers and Knoop indenters. These two indenters adopt the independent alignment device which ensures that Vickers and Knoop indentation are at the same center position.
iVick-457HK can directly show the test mode, test force, indentation length, dwell time, test numbers, conversion scale, date and time on the large screen.
Just press the eyepiece button after measuring the indentation length, it can automatically get the hardness value and shows on the screen.
With up and down limit alarm function, test results can be saved for checking or be printed out by the built-in printer, and with RS232 interface for connecting to the computer.
Available to use optional Knoop indenter to measure Knoop hardness.
Support to equip with LCD video measuring device and CCD image automatic measuring system.
Application range:
Suitable for ferrous metal, non-ferrous metals, IC thin sections, coatings, ply-metals; glass, ceramics, agate, precious stones, thin plastic sections etc.; hardness testing such as that on the depth and the trapezium of the carbonized layers and quench hardened layers.
Technical Specification:
Model | iVick-457HK | |
Test Force | gf | 10gf, 25gf, 50gf, 100gf, 200gf, 300gf, 500gf, 1000gf |
N | 0.098N, 0.246N, 0.49N, 0.98N, 1.96N, 2.94N, 4.90N, 9.80N | |
Test Range | 1HV~2967HV | |
Test Mode | HV/HK | |
Loading Method | Automatic (Loading/Dwell/Unloading) | |
Turret | Automatic Turret (Two Indenters, Three Objectives) | |
Conversion Scale | HV, HK, HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRK, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T, HS, HBW | |
Data Output | Built-in Printer, RS232 Interface | |
Hardness Reading | LCD Display, Data can be saved | |
Objective | 10x (Observe), 20x (Measure), 40x (Measure) | |
Eyepiece | 10x | |
Total Magnification | 100x, 200x, 400x | |
Resolution | 0.03μm, 0.015μm | |
Dwell Time | 0~95s | |
Light Source | Halogen Lamp | |
X-Y Test Table | Size: 100×100mm; Travel: 25×25mm; Resolution: 0.01mm | |
Max. Height of Specimen | 90mm | |
Throat | 120mm | |
Power Supply | AC220V/50Hz/1Ph | |
Execute Standard | ISO 6507, ASTM E384, JIS Z2244, GB/T 4340.2 | |
Dimension | 495×305×550mm, Packing Dimension: 600×360×800mm | |
Weight | Net Weight: 35kg, Gross Weight: 44kg |
Packing List:
Name | Qty | Name | Qty |
Instrument Main Body | 1 set | 10x Digital Measuring Eyepiece | 1 pc |
Diamond Micro Vickers Indenter | 1 pc | Diamond Knoop Indenter | 1 pc |
10x, 20x, 40x Objective | each 1 pc | Weights | 7 pcs |
Power Cable | 1 pc | Cross Test Table | 1 pc |
Thin Specimen Test Table | 1 pc | Flat Clamping Test Table | 1 pc |
Filament Clamping Test Table | 1 pc | Level | 1 pc |
Horizontal Regulating Screw | 4 pcs | Halogen Lamp 12V/15~20W | 1 pc |
Fuse 1A | 2 pcs | Screw Driver | 1 pc |
Inner Hexagon Spanner | 1 pc | Color Filter | 1 pc |
Plastic Absorbing Plate | 1 pc | Hardness Block 400~500 HV0.2 | 1 pc |
Hardness Block 700~800 HV1 | 1 pc | Hardness Block 700~800 HK1 | 1 pc |
Anti-dust Cover | 1 pc | Usage Instruction Manual | 1copy |
Spare Parts:
The Vickers hardness test method consists of indenting the test material with a diamond indenter, in the form of a right pyramid with a square base and an angle of 136 degrees between opposite faces subjected to a load of 1 to 100 kgf. The full load is normally applied for 10 to 15 seconds.
The two diagonals of the indentation left in the surface of the material after removal of the load are measured using a microscope and their average calculated. The area of the sloping surface of the indentation is calculated. The Vickers hardness is the quotient obtained by dividing the kgf load by the square mm area of indentation.
When the mean diagonal of the indentation has been determined the Vickers hardness may be calculated from the formula, but is more convenient to use conversion tables.
The Vickers hardness should be reported like 800 HV/10, which means a Vickers hardness of 800, was obtained using a 10kgf force. Several different loading settings give practically identical hardness numbers on uniform material, which is much better than the arbitrary changing of scale with the other hardness testing methods.
The advantages of the Vickers hardness test are that extremely accurate readings can be taken, and just one type of indenter is used for all types of metals and surface treatments. Although thoroughly adaptable and very precise for testing the softest and hardest of materials, under varying loads, the Vickers machine is a floor standing unit that is more expensive than the Brinell or Rockwell machines.
Contact Person: Mr. Raymond Chung
Tel: 86-13711988687
Fax: 86-769-22784276